Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ther Drug Monit ; 36(4): 448-55, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24452065

RESUMO

BACKGROUND: The corticosteroid prednisone is an important component of posttransplantation immunosuppressive therapy. Pharmacokinetic parameters of prednisone or its pharmacologically active metabolite, prednisolone, are not well characterized in transplant recipients. The objective of this study was to compare the pharmacokinetics of total and unbound prednisone and prednisolone in diabetic and nondiabetic stable kidney transplant recipients and to evaluate the factors influencing plasma protein binding of prednisolone. METHODS: Prednisone and prednisolone concentration-time profiles were obtained in 20 diabetic and 18 nondiabetic stable kidney transplant recipients receiving an oral dose of 5-10 mg prednisone per day. In addition to drug and metabolite exposures, factors influencing prednisolone protein binding were evaluated using a nonlinear mixed-effects modeling approach. This model takes into account the binding of prednisolone and cortisol to corticosteroid-binding globulin (CBG) in a saturable fashion and binding of prednisolone to albumin in a nonsaturable fashion. Finally, we have investigated the influence of several covariates including diabetes, glucose concentration, hemoglobin A1c, creatinine clearance, body mass index, gender, age, and time after transplantation on the affinity constant (K) between corticosteroids and their binding proteins. RESULTS: In patients with diabetes, the values of dose-normalized area under the concentration-time curves were 27% and 23% higher for total and unbound prednisolone, respectively. Moreover, the ratio of total prednisolone to prednisone concentrations (active/inactive forms) was higher in diabetic subjects (P < 0.001). Modeling protein binding results revealed that the affinity constant of corticosteroid-binding globulin-prednisolone (KCBG,PL) was related to the patient's gender and diabetes status. CONCLUSIONS: Higher prednisolone exposure could potentially lead to the increased risk of corticosteroid-related complications in diabetic kidney transplant recipients.


Assuntos
Anti-Inflamatórios/farmacocinética , Diabetes Mellitus/metabolismo , Rim/metabolismo , Prednisolona/farmacocinética , Prednisona/farmacocinética , Corticosteroides/metabolismo , Idoso , Idoso de 80 Anos ou mais , Anti-Inflamatórios/uso terapêutico , Área Sob a Curva , Feminino , Glucocorticoides/metabolismo , Humanos , Rim/efeitos dos fármacos , Rim/cirurgia , Transplante de Rim/métodos , Masculino , Prednisolona/uso terapêutico , Prednisona/uso terapêutico , Ligação Proteica , Transplantados
2.
Anal Bioanal Chem ; 402(3): 1217-27, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22108655

RESUMO

A simple and sensitive assay was developed and validated for the simultaneous quantification of rosuvastatin acid (RST), rosuvastatin-5S-lactone (RST-LAC), and N-desmethyl rosuvastatin (DM-RST), in buffered human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). All the three analytes and the corresponding deuterium-labeled (d6) internal standards were extracted from 50 µL of buffered human plasma by protein precipitation. The analytes were chromatographically separated using a Zorbax-SB Phenyl column (2.1 mm × 100 mm, 3.5 µm). The mobile phase comprised of a gradient mixture of 0.1% v/v glacial acetic acid in 10% v/v methanol in water (solvent A) and 40% v/v methanol in acetonitrile (solvent B). The analytes were separated at baseline within 6.0 min using a flow rate of 0.35 mL/min. Mass spectrometry detection was carried out in positive electrospray ionization mode. The calibration curves for all three analytes were linear (R ≥ 0.9964, n = 3) over the concentration range of 0.1-100 ng/mL for RST and RST-LAC, and 0.5-100 ng/mL for DM-RST. Mean extraction recoveries ranged within 88.0-106%. Intra- and inter-run mean percent accuracy were within 91.8-111% and percent imprecision was ≤15%. Stability studies revealed that all the analytes were stable in matrix during bench-top (6 h on ice-water slurry), at the end of three successive freeze and thaw cycles and at -80°C for 1 month. The method was successfully applied in a clinical study to determine the concentrations of RST and the lactone metabolite over 12-h post-dose in patients who received a single dose of rosuvastatin.


Assuntos
Fluorbenzenos/sangue , Lactonas/sangue , Pirimidinas/sangue , Sulfonamidas/sangue , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/economia , Cromatografia Líquida/métodos , Humanos , Rosuvastatina Cálcica , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/economia
3.
Anal Bioanal Chem ; 400(2): 423-33, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21359569

RESUMO

The aim of the proposed work was to develop and validate a simple and sensitive assay for the analysis of atorvastatin (ATV) acid, ortho- and para-hydroxy-ATV, ATV lactone, and ortho- and para-hydroxy-ATV lactone in human plasma using liquid chromatography-tandem mass spectrometry. All six analytes and corresponding deuterium (d5)-labeled internal standards were extracted from 50 µL of human plasma by protein precipitation. The chromatographic separation of analytes was achieved using a Zorbax-SB Phenyl column (2.1 mm × 100 mm, 3.5 µm). The mobile phase consisted of a gradient mixture of 0.1% v/v glacial acetic acid in 10% v/v methanol in water (solvent A) and 40% v/v methanol in acetonitrile (solvent B). All analytes including ortho- and para-hydroxy metabolites were baseline-separated within 7.0 min using a flow rate of 0.35 mL/min. Mass spectrometry detection was carried out in positive electrospray ionization mode, with multiple-reaction monitoring scan. The calibration curves for all analytes were linear (R(2) ≥ 0.9975, n = 3) over the concentration range of 0.05-100 ng/mL and with lower limit of quantitation of 0.05 ng/mL. Mean extraction recoveries ranged between 88.6-111%. Intra- and inter-run mean percent accuracy were between 85-115% and percent imprecision was ≤ 15%. Stability studies revealed that ATV acid and lactone forms were stable in plasma during bench top (6 h on ice-water slurry), at the end of three successive freeze and thaw cycles and at -80 °C for 3 months. The method was successfully applied in a clinical study to determine concentrations of ATV and its metabolites over 12 h post-dose in patients receiving atorvastatin.


Assuntos
Anticolesterolemiantes/sangue , Cromatografia Líquida de Alta Pressão/métodos , Ácidos Heptanoicos/sangue , Lactonas/sangue , Pirróis/sangue , Espectrometria de Massas em Tandem/métodos , Anticolesterolemiantes/administração & dosagem , Anticolesterolemiantes/metabolismo , Atorvastatina , Ácidos Heptanoicos/administração & dosagem , Ácidos Heptanoicos/metabolismo , Humanos , Lactonas/metabolismo , Limite de Detecção , Pirróis/administração & dosagem , Pirróis/metabolismo
4.
J Chromatogr B Analyt Technol Biomed Life Sci ; 878(19): 1629-33, 2010 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20434409

RESUMO

Midazolam is an ultra short acting benzodiazepine derivative and a specific probe for phenotyping cytochrome P450 (P450) 3A4/5 activity. A rapid, sensitive, and selective LC-MS/MS method was developed for simultaneous quantitation of midazolam and its metabolites (1'-hydroxymidazolam and 4-hydroxymidazolam). Deuterated (D5) analog of midazolam was utilized as an internal standard. Sample preparation either from human plasma (100 microL) or liver microsomal incubations involved a simple protein precipitation using acetonitrile (900 microL) with an average recovery of >90% for all compounds. The chromatographic separation was achieved using Zorbax-SB Phenyl, Rapid Resolution HT (2.1 mm x 100 mm, 3.5 microm) and a gradient elution with 10 mM ammonium acetate in 10% methanol (A) and acetonitrile (B). The flow rate was 0.25 mL/min and total run time was 5.5 min. Calibration curves were linear over the concentration range of 0.100-250 ng/mL. The lower limit of quantitation (LLOQ) was 0.1 ng/mL for all three analytes. The accuracy and precision, estimated at LLOQ and three concentration levels of quality control samples in six replicates, were within 85-115%. In conclusion, a robust, simple and highly sensitive analytical method was developed and validated for the analysis of midazolam and its metabolites. This method is suitable for characterizing the P450 3A4/5 activity in vitro or in human pharmacokinetic studies allowing administration of smaller doses of midazolam.


Assuntos
Cromatografia Líquida/métodos , Midazolam , Espectrometria de Massas em Tandem/métodos , Humanos , Análise dos Mínimos Quadrados , Microssomos Hepáticos , Midazolam/análogos & derivados , Midazolam/análise , Midazolam/sangue , Midazolam/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Chromatogr B Analyt Technol Biomed Life Sci ; 877(8-9): 765-72, 2009 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-19237320

RESUMO

A highly selective, sensitive and robust LC-MS/MS method was developed for the simultaneous quantification of cortisol, cortisone, prednisolone and prednisone in human plasma. Prednisolone, cortisol and cortisone have similar fragmentation pattern. These three compounds were chromatographically separated, thus eliminating the inherent interference that fragments derived from the M+2 and M isotopes of prednisolone contribute in the MRM channels of cortisol and cortisone, respectively. Additionally, by using a small particle (1.8 microm) analytical column, interferences present in the plasma samples from post-transplant recipients were successfully resolved from cortisol after a simple extraction consisting of protein precipitation, evaporation and reconstitution. The chromatographic separation was achieved on a Zorbax-SB Phenyl column under isocratic conditions during a run time of 8 min. Intra-run and inter-run precision and accuracy within +/-15% were achieved during a 3-run validation for quality control samples at five concentration levels in charcoal-stripped plasma as well as in normal plasma, over a 500-fold dynamic concentration range. The lower limit of quantitation was 0.500 ng/mL for cortisone and prednisone, 1.00 ng/mL for cortisol and 2.00 ng/mL for prednisolone. The performance of the small particle column was maintained during more than 1200 injections in terms of peak retention time, symmetry and backpressure.


Assuntos
Cromatografia Líquida/métodos , Cortisona/sangue , Hidrocortisona/sangue , Prednisolona/sangue , Prednisona/sangue , Espectrometria de Massas em Tandem/métodos , Humanos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...